How hot should my wood stove pipe be?

450 degrees F.
A good rule of thumb is to get the temperature up to a stovepipe thermometer reading of 450 degrees F. for the first half-hour, and to keep it at an average of 300 degrees thereafter, each day that you start your stove.

How hot should twin wall flue get?

How hot does twin wall flue get? Twin wall flues will heat up when in use as they transport the hot stove gases away from the appliance, the outer part of the flue can be over 90o C or 194o F.

How hot does the outside of a triple wall stove pipe get?

The outside of insulated chimney can probably hit temperatures of 500 degrees or hotter…still, the temperatures on the wood 2″ away would remain very low.

What is the purpose of double wall stove pipe?

Double Wall Black Stove Pipes The double wall construction keeps the outside cooler and thus reduces wall clearances to 6 inches and ceiling clearances to 8 inches.

What temperature is too hot for a wood stove?

There are many ways to combat or prevent this, and one of them is to keep the flue warmer than 250 degrees Fahrenheit. Temperatures above this point are too hot for creosote to condense on the surface of the chimney flue.

How hot does a single wall flue get?

150 to 250 degrees centigrade
If you have not used or owned a stove before you might not be aware quite how hot the stove and the flue pipe can get. In normal operation a flue pipe will be at 150 to 250 degrees centigrade but can go a lot higher.

Does twin wall flue pipe get hot?

When do you have to box in twin wall flue pipe This guard should be further away from its designated distance to combustibles. Typically this clearance distance is 50mm or 60mm, but it does vary. Twin wall flue doesn’t normally get that hot on the outside so you might not think this is too much of a problem.

How hot can single wall stove pipe get?

For safety reasons, UL specifies that manufactured chimneys must be able to sustain a continuous flue gas temperature of 1000ºF. That would correspond to about a 500-600º external temp on single-wall black stove pipe.

What should outside temp of double wall stove pipe be?

The outside temp of a double wall pipe is just almost next to meaningless. Heck the gentle breeze of a ceiling fan is enough to throw the temps off far enough to be completely disregarded. Get the probe dude. Quad – Isle Royale – 480 pounds of cast iron beauty.

How does a double wall stove pipe work?

The outside of the double wall pipe is getting heating by both the direct heat coming from the stove top and the heat radiated by the hot flue gases. The point of the flue thermometer is to know the temperature of the flue gases heading up the inside of the pipe.

What is the maximum temperature for double wall black pipe?

The maximum temperature must not exceed 1000°F continuous and 1700°F intermittent. The Double Wall Black Pipe is listed for six (6) inches clearance to combustible material. NEVER enclose this connector pipe or use it as a chimney to install through ceilings, walls or inaccessible areas.

When to change stove pipe to chimney pipe?

Stove pipe must change to chimney pipe when it enters the wall. Double wall chimney pipes are designed to protect buildings from high temperatures generated by some heating appliances.